ELIAR

P 3XX Series | Hydrostatic Level Sensor

P3xx works by measuring the water pressure which is proportional to the water level in a tank.
The output is a standard two-wire, 4-20 mA current loop.
The sensor needs an air isolated mounting method. The position of the sensor should be above the highest water level.

Technical Specification For P 3XX Series | Hydrostatic Level Sensor
Parameter
Specification
Input
P300: 0–100 mBar
P320: 0–200 mBar
P330: 0–300 mBar
P340: 0–400 mBar
P350: 0–500 mBar
Media Isolation
Air
Output
4–20 mA
Excitation Voltage
24 V DC (18–30 V DC)
Load Driving (max)
500 Ohm (24 V DC)
Operating Temperature
0 – 60 °C
Over Pressure
750 mBar
Linearity
< 1%
Mechanical Connection
1/4’’ BSP
Weight
145 gr
Cable Length
2 m
Environmental Rating
IP65
Scroll to Top